Products
PRODUCT QUICKLIST

   
Our Products » Precision Digital Instrument Meter & Controllers » Hazardous Area Meters & Instruments »
ProtEx-Max Series

The ProtEX-MAX Series has been designed to offer the functions and features of any ProVu®, Trident X2, or Snooper model in a great looking explosion-proof housing.

Features:

  • Modern, Sleek and Practical Enclosure.
  • All models available with sunlight readable displays.
  • Display Mountable at 0°, 90°, 180°, & 270° Degrees.
  • Explosion-Proof, IP68, NEMA 4X Enclosure.
  • Models Available with ProVu®, Trident X2, or Snooper Functionality.
  • SafeTouch® Through-Glass Button Programming.
  • Password Protection.
  • Modbus® RS-485 Serial Communications.
  • Flanges for Wall or Pipe Mounting.
Product Sheet
1. PD8-6080 ProtEX-MAX Super Snooper Modbus Serial Input Scanner
Features:

  • Modbus RTU master, slave, or snooper mode with RS-485 serial communications.
  • Master mode to can up to 16 Modbus PVs from Modbus transmitters.
  • Snooper mode to scan up to 16 Modbus PVs polled by a different Modbus master.
  • Up to Four Math Channels for Addition, Difference, Average, Ratio & More.
  • SafeTouch through-glass button programming.
  • Isolated 24 VDC @ 25 mA transmitter power supply.
  • 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V Inputs.
Data Sheet   Video Demo

2. PD8-6081 ProtEX-MAX Super Snooper Feet & Inches Modbus Serial Input Scanner
Features:

  • Display level in feet and inches.
  • Modbus RTU master, slave, or snooper mode with RS-485 serial communications.
  • Master mode to can up to 16 Modbus PVs from Modbus level or multivariable transmitters.
  • Snooper mode to scan up to 16 Modbus PVs polled by a different Modbus master.
  • Up to four math channels for addition, difference, average, ratio & more.
  • SafeTouch through-glass button programming.
  • Isolated 24 VDC @ 25 mA transmitter power supply.
  • 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V inputs.
Data Sheet   Video Demo

3. PD8-6000 Process Meter
Features:

  • Dual-scale for level applications - single input.
  • Isolated 24 VDC @ 200 mA transmitter power supply.
  • 32-point, square root, or exponential linearization.
  • Multi-pump alternation control.
  • SafeTouch® through-glass button programming.
  • Modbus® RS-485 serial communications.
  • Flanges for wall or pipe mounting.
  • Isolated 24 VDC @ 200 mA transmitter power supply.
Data Sheet

4. PD8-6060 ProtEX-MAX Dual-Input Process Meter
Features:

  • Addition, difference, absolute difference, average, multiplication, division, min of A or B, max of A or B, draw, weighted average, and ratio math functions.
  • Signal input conditioning for flow & round horizontal tanks.
  • Multi-pump alternation control.
  • SafeTouch® through-glass button programming.
  • Modbus® RS-485 serial communications.
  • Flanges for wall or pipe mounting.
  • Isolated 24 VDC @ 200 mA transmitter power supply.
Data Sheet

5. PD8-6200 ProtEX-MAX Analog Input Rate/Totalizerr
Features:

  • Displays rate and total simultaneously.
  • Open channel flow with programmable exponent.
  • Isolated 24 VDC @ 200 mA transmitter power supply.
  • 32-point linearization with free software.
  • Total, grand total, or non-resettable grand total.
  • SafeTouch® through-glass button programming.
  • Modbus® RS-485 serial communications.
  • Flanges for wall or pipe mounting.
  • Isolated 24 VDC @ 200 mA transmitter power supply.
Data Sheet

6. PD8-6300 ProtEX-MAX Pulse Input Rate/Totalizer
Features:

  • Displays rate and total simultaneously.
  • 5, 10, or 24 VDC flowmeter power supply.
  • Gate function for rate display of slow pulse rates.
  • 4-20 mA output option converts the pulse input to an isolated 4-20 mA output.
  • SafeTouch® through-glass button programming.
  • Modbus® RS-485 serial communications.
  • Flanges for wall or pipe mounting.
  • Isolated 24 VDC @ 200 mA transmitter power supply.
Data Sheet

7. PD8-6210 ProtEX-MAX Analog Input Batch Controller
Features:

  • Start, batch, & stop with pause front panel buttons.
  • Display batch total + rate, grand total, batch count or preset.
  • Single or multi-stage batching with up to 8 relays.
  • Automatic overflow correction.
  • Manual control or automatic batching.
  • SafeTouch® through-glass button programming.
  • Modbus® RS-485 serial communications.
  • Flanges for wall or pipe mounting.
  • Isolated 24 VDC @ 200 mA transmitter power supply.
  • Grand total can count up or down.
Data Sheet

8. PD8-6310 ProtEX-MAX Pulse Input Batch Controller
Features:

  • Start, batch, & stop with pause front panel buttons.
  • Display batch total + rate, grand total, batch count or preset.
  • Single or multi-stage batching with up to 8 relays.
  • Automatic overflow correction.
  • Manual control or automatic batching.
  • SafeTouch® through-glass button programming.
  • Modbus® RS-485 serial communications.
  • Flanges for wall or pipe mounting.
  • Isolated 24 VDC @ 200 mA transmitter power supply.
  • Total can count up or down.
Data Sheet

9. PD8-7000 ProtEX-MAX Temperature Meter
Features:

  • 1° or 0.1° resolution.
  • Averages up to 10 RTD sensors.
  • Automatic cold junction compensation.
  • Interlock relays (force on).
  • SafeTouch® through-glass button programming.
  • Modbus® RS-485 serial communications.
  • Flanges for wall or pipe mounting.
Data Sheet

10. PD8-6100 ProtEX-MAX Strain Gauge Meter
Features:

  • Selectable 5, 10, or 24 VDC excitation power supply.
  • Capture or programmable tare feature.
  • Ratiometric operation.
  • Dual-scale feature - single input.
  • Rounding function 1, 2, 5, 10, 20, 50, or 100.
  • Auto-zero feature eliminates zero drift.
  • SafeTouch® through-glass button programming.
  • Modbus® RS-485 serial communications.
  • Flanges for wall or pipe mounting.
  • Isolated 24 VDC @ 200 mA transmitter power supply.
Data Sheet

11. PD8-765 ProtEX-MAX Process & Temperature Meter
Features:

  • Sunlight readable display.
  • Maximum/minimum display.
  • Linear or square root with low-flow cutoff.
  • Transmitter power option.
  • SafeTouch® through-glass button programming.
  • Modbus® RS-485 serial communications.
  • Flanges for wall or pipe mounting.
Data Sheet

12. PD8-865 ProtEX-MAX Modbus Serial Input Meter
Features:

  • Master, slave, or snooper mode.
  • 2 form A relays.
  • Linear, square root, or programmable exponent.
  • RS-485 serial communications.
  • Proxy polling for up to 8 process variables.
  • SafeTouch® through-glass button programming.
  • Modbus® RS-485 serial communications.
  • Flanges for wall or pipe mounting.
Data Sheet
 
Copyright © 2009-2017 Nationwide Oil & Gas Sdn Bhd (573654-D). All Rights Reserved